Oxygen/Nitrogen Improvement Systems: Dissolved Oxygen Calculation

Click here for a printable Oxygen/Nitrogen Systems form


Optimal oxygen levels are a vital factor in promoting healthy fish and high yield in the hatchery business. The following calculations can assist you in determining dissolved oxygen efficiencies.

VMG Industries manufactures two oxygen/nitrogen improvement systems, GASTAC and Inline-Ox. We can help you evaluate which system is best for your operation. Go to Oxygen/Nitrogen Systems, and complete the online form. VMG will provide you a recommendation based on your data.


STEP ONE


How much oxygen is needed?
Use the following if you know gallons per minute water flow and the desired increase in oxygen in ppm of 02:


= Increase in dissolved oxygen

• 378 = one liter of pure oxygen per minute treats 378 gallons per minute of water at 100% oxygen injection efficiency.

• Use the decimal equivalent of the percentage in the following Formula for Efficiency. (50% efficiency = .50)

Note: 3.78 liters = one gallon of water

Use the following to convert liters per minute of needed 02 to cubic feet per hour:


• 28.32 liters = 1 cubic foot of 02